许超,田庆业,范飞虎.微米量级腔长的开式F-P腔研制及其折射率传感特性[J].光学技术,2025,51(04):432-438.
XU Chao,TIAN Qingye,FAN Feihu.Open Fabry-Pérot cavity with micrometer scale cavity length and its refractive index sensing characteristics[J].OPTICAL TECHNIQUE,2025,51(04):432-438.
F-P谐振腔(Fabry-Pérot cavity)广泛用于折射率、温度、压力等传感,现有的基于光纤-谐振腔的封闭式F-P传感器因为谐振腔较长,限制了待测物质种类及其测量范围。基于薄膜技术研制了短腔长的开式F-P折射率传感器,具备宽测量范围和高灵敏度。理论研究了腔镜反射率和腔长对开式F-P腔特性参数的影响规律,设计开式F-P谐振腔折射率传感器,包含上下高反射率腔镜(99.7%)和短腔(3.305μm),仿真结果表明,其自由光谱范围高达42nm,折射率测量范围高于传统F-P腔一个数量级,达到0.129 RIU(RIU为折射率单位)。采用电子束热蒸发薄膜沉积和光刻技术研制了折射率传感器,并搭建折射率测试验证装置,开展了折射率测试实验。结果表明,折射率变化导致的中心波长平均改变1.79 nm/RIU,测试灵敏度为346.65nm/RIU。该研究为低成本、宽测量范围、高精度液体/气体折射率传感器奠定理论和实践基础。
F-P optical resonant cavity (Fabry-Pérot cavity) is widely used for sensing refractive index
temperature
pressure
etc. The closed fiber F-P resonant cavity limits the types of substances to be measured and their measurement range due to the long resonant cavity. Herein
a short cavity length open F-P refractive index sensor was designed and fabricated based on thin film technology and lithography
which definitely increases the measurement range and high sensitivity
and is suitable for gases and liquids. Theoretical research was conducted on the influence of mirror reflectivity and cavity length on the sensitive parameters of open F-P cavity
and an open F-P resonant cavity structure and characteristics were all determined
including upper and lower high reflectivity mirrors (99.7%) and short cavity length (3.305 μm). The FDTD simulation results showed that its free spectral range was as high as 42nm
the sensitivity was as high as 385.85nm per Refractive Index Unit (RIU)
and the refractive index measurement range was one order of magnitude higher than traditional F-P cavities
reaching to 0.129RIU. In addition
a refractive index testing and verification system was built
and refractive index testing experiments were all carried out. Experimental verification showed that the greater the change in refractive index
the greater the shift in the center wavelength. The average change in the center wavelength was 1.79 nm/RIU
and the experimental sensitivity was determined to 346.65 nm/RIU. The results lay a theoretical and practical foundation for low-cost
wide measurement range
and high-precision liquid/gas refractive index sensors.
Xavier J , Yu D , Jones C , et al . Quantum nanophotonic and nanoplasmonic sensing: towards quantum optical bioscience laboratories on chip [J ] . Nanophotonics , 2021 , 10 ( 5 ): 1387 — 1435 .
Kunz R , Cottier K . Optimizing integrated optical chips for label-free bio-chemical sensing [J ] . Analytical and bioanalytical chemistry , 2006 , 384 ( 1 ): 180 — 190 .
Chen W , Kaya O S , Zhao G , et al . Exceptional points enhance sensing in an optical microcavity [J ] . Nature , 2017 , 548 ( 7666 ): 192 — 196 .
Vahala K J . Optical microcavities [J ] . Nature , 2003 , 424 ( 6950 ): 839 — 846 .
Yoshie T , Tang L , Su S . Optical microcavity: sensing down to single molecules and atoms [J ] . Sensors , 2011 , 11 ( 2 ): 1972 — 1991 .
Bitarafan M H , Decorby R G . On-chip High-finesse Fabry-perot microcavities for optical sensing and quantum information [J ] . Sensors (Basel) , 2017 , 17 ( 8 ): 1748 .
Fan H , Gu X , Zhou D , et al . Confined whispering-gallery mode in silica double-toroid microcavities for optical sensing and trapping [J ] . Optics Communications , 2019 , 434 : 97 — 103 .
Yang D , Kita S , Liang F , et al . High sensitivity and high Q-factor nanoslotted parallel quadrabeam photonic crystal cavity for real-time and label-free sensing [J ] . Applied Physics Letters , 2014 , 105 ( 6 ): 063118 .
Islam M R , Ali M M , Lai M H , et al . Chronology of Fabry-Perot interferometer fiber-optic sensors and their applications: a review [J ] . Sensors , 2014 , 14 ( 4 ): 7451 — 88 .
Liu Y , Qu S . Optical fiber Fabry-Perot interferometer cavity fabricated by femtosecond laser-induced water breakdown for refractive index sensing [J ] . Appl Opt , 2014 , 53 ( 3 ): 469 — 74 .
Tian J , Lu Z , Quan M , et al . Fast response Fabry-Perot interferometer microfluidic refractive index fiber sensor based on concave-core photonic crystal fiber [J ] . Opt Express , 2016 , 24 ( 18 ): 20132 — 42 .
Fu X , Liu L , Huang S , et al . Simultaneous measurement of temperature and refractive index with F–P microcavity sensor based on graded-index few mode fiber [J ] . Optics Communications , 2020 ,( 455 ): 124577 .
Yu X , Wang S , Jiang J , et al . Hybrid sapphire Dual-fabry—Perot-cavities sensor for high temperature and refractive index measurement [J ] . Journal of Lightwave Technology , 2021 , 39 ( 12 ): 3911 — 3918 .
Tao J , Zhang Q , Xiao Y , et al . A Microfluidic-based Fabry-perot gas sensor [J ] . Micromachines , 2016 , 7 ( 3 ): 36 .
Vallance C , Trichet A A , James D , et al . Open-access microcavities for chemical sensing [J ] . Nanotechnology , 2016 , 27 ( 27 ): 274003 .
韩超 , 邱诚玉 , 侯梦迪 , 等 . 基于光微流单模激光的液体折射率测量 [J ] . 激光与光电子学进展 , 2018 , 55 ( 08 ): 333 — 338 .
Han Chao , Qiu Chenyu , Hou Mengdi , et al . Measurement of liquid refractive index based on optofluidic single mode laser [J ] . Laser &Optoelectronics Progress , 2018 , 55 ( 08 ): 333 — 338 .
张宇光 , 李鹏 , 王丽 , 等 . 外界环境对微球腔品质因数的影响 [J ] . 光子学报 , 2011 , 40 ( 05 ): 803 — 806
Zhang Yuguang , Li Peng , Wang Li , et al . Effect of the environment on microsphere Q-factor [J ] . Acta Photonica Sinica , 2011 , 40 ( 05 ): 803 — 806 .