针对在体皮肤光学层析成像中MEMS振镜扫描系统与高层析能力物镜的匹配难题,设计了一款工作波段为830nm的高分辨率共聚焦显微物镜,旨在克服因生物组织球差导致的成像深度受限与跨介质像差平衡问题。设计采用基于皮肤多层光学模型的多目标优化方法,在2mm入瞳直径的约束下,实现了成像深度达到300μm,横向分辨率优于0.83μm,轴向分辨率优于4.05μm,全视场波前误差优于λ/16,在皮肤表面及各组织深度处的MTF均与衍射极限紧密贴合。该设计通过多深度像差协同优化
为便携式在体皮肤光学层析成像系统提供了可靠的光学解决方案。
Aiming at the matching problem between the MEMS galvanometer scanning system and the high-resolution objective lens in in vivo skin optical tomography
a high-resolution confocal microscope objective with a working band of 830 nm is designed to overcome the imaging depth limitation and cross-media aberration balance caused by the spherical aberration of biological tissue. The design adopts a multi-objective optimization method based on the skin multi-layer optical model. Under the constraint of 2mm entrance pupil diameter
the imaging depth reaches 300μm
the lateral resolution is better than 0.83μm
the axial resolution is better than 4.05μm
and the full-field wavefront error is better than λ / 16. The MTF at the skin surface and the depth of each tissue is closely fitted with the diffraction limit. This design provides a reliable optical solution for portable in vivo skin optical tomography system through multi-depth aberration collaborative optimization.
Boostani M , Bozsányi S , Suppa M , et al . Novel imaging techniques for tumor margin detection in basal cell carcinoma: a systematic scoping review of FDA and EMA-approved imaging modalities [J ] . International Journal of Dermatology , 2024 , 64 ( 2 ): 287 — 301 .
Arnaud D , Olivier L , Hicham A , et al . Line-field confocal optical coherence tomography for high-resolution noninvasive imaging of skin tumors [J ] . Journal of Biomedical Optics , 2018 , 23 ( 10 ): 1 — 9 .
Hibler B , Sierra H , Cordova M , et al . Carbon dioxide laser ablation of basal cell carcinoma with visual guidance by reflectance confocal microscopy: a proof-of-principle pilot study [J ] . The British Journal of Dermatology , 2016 , 174 ( 6 ): 1359 — 64 .
Pathak N G , Parikh K A , Saifullah A , et al . Applications of reflectance confocal microscopy in photoaging and aesthetic conditions: skin characterization and treatment monitoring [J ] . Archives of Dermatological Research , 2025 , 317 ( 1 ): 538 — 538 .
Liu T , Rajadhyaksha M , Dickensheets L D . MEMS-in-the-lens architecture for a miniature high-NA laser scanning microscope [J ] . Light: Science & Applications , 2019 , 8 ( 1 ): 1 — 11 .
范娜娜 , 王懋 , 温少聪 , 等 . 基于二维MEMS振镜的激光雷达系统的光学设计 [J ] . 光学技术 , 2020 , 46 ( 03 ): 290 — 294 .
Fan Nannan , Wang Mao , Wen Shaocong , et al . Optical design of laser radar system based on two - dimensional MEMS galvanometer [J ] . Optical Technology , 2020 , 46 ( 03 ): 290 — 294 .
Priyadharsini N . Ceruminous neoplasms of the ear [J ] . Head and Neck Pathology , 2018 , 12 ( 3 ): 350 — 361 .
Obeidy P , Tong L P , Weninger W . Research techniques made simple: two-photon intravital imaging of the skin [J ] . Journal of Investigative Dermatology , 2018 , 138 ( 4 ): 720 — 725 .
Ratnam M R , Chen L , Troy H G , et al . Deep learning-based adaptive optics for light sheet fluorescence microscopy [J ] . Biomedical Optics Express , 2023 , 14 ( 6 ): 2905 — 2919 .
Bachir , Wesam , Dargham A , et al . Feasibility of 830 nm laser imaging for vein localization in dark skin tissue-mimicking phantoms [J ] . Physical and Engineering Sciences in Medicine , 2022 , 45 ( 1 ): 1 — 8 .
郑骏笙 , 吴海啸 , 胡燕海 . 不同肤色条件下新生儿皮肤可见光漫反射研究 [J ] . 激光与光电子学进展 , 2022 , 59 ( 16 ): 500 — 505 .
Zheng Junsheng , Wu Haixiao , Hu Haiyan . Study on visible light diffuse reflectance of neonatal skin under different skin color conditions [J ] . Laser & Optoelectronics Progress , 2022 , 59 ( 16 ): 500 — 505 .
Yoo H , Verhaegen M , Houtsmuller A , et al . Automated spherical aberration correction in scanning confocal microscopy [J ] . The Review of Scientific Instruments , 2014 , 85 ( 12 ): 123706 .
Moon B , Poletti M , Roorda A , et al . Alignment, calibration, and validation of an adaptive optics scanning laser ophthalmoscope for high-resolution human foveal imaging [J ] . Applied Optics , 2024 , 63 ( 3 ): 730 — 742 .